Got a bet with a friend about the "correct" way to flush a JP Drain. What is the correct way, from your experience? Sounds simple, but I want to prove him wrong....

Thanks:chuckle

Share this post


Link to post
Share on other sites

283 Posts; 3,963 Profile Views

Ummm... first you have to disconnect the JP bulb from the tubing. Then, I use a 3, 5, or 10 cc syringe (needle removed, of course) and flush it with NS. Trouble is, if the tubing is a smaller diameter than the tip of the syringe, it's kinda messy.

Just a friendly (emphasis on FRIENDLY) hint... avoid putting people in their place, or trying to prove them wrong... because sooner or later, you'll have your own opportunity to eat a little crow. :)

Share this post


Link to post
Share on other sites

427 Posts; 7,381 Profile Views

make sure you go slow or you could dislodge the drain.

Share this post


Link to post
Share on other sites

283 Posts; 3,963 Profile Views

Originally posted by kewlnurse

make sure you go slow or you could dislodge the drain.

Agreed!! :wink2:

Share this post


Link to post
Share on other sites

49 Posts; 2,575 Profile Views

Why are you flushing a JP? They are usually attached to a bulb or hemovac primed suction.

Share this post


Link to post
Share on other sites

8 Posts; 1,227 Profile Views

Have encountered a couple of instances where the docs wished for the JP's to be flushed with 10cc NS tid to prevent blockage--even with the bulb suction, apparently these particular patients still had drains that became non-patent.

Share this post


Link to post
Share on other sites

49 Posts; 2,575 Profile Views

lori999'

Thanks. I learn something every day.

Share this post


Link to post
Share on other sites

4 Posts; 801 Profile Views

Me too Caron, I never knew that flushing a JP was an option! I have never done it! I am guessing it requires a doctor's order? I thought this was weird, though, once I hooked a JP up to wall suction, using a special connector.

Share this post


Link to post
Share on other sites

723 Posts; 10,854 Profile Views

Ewwwww (JP to wall suction) . I never flushed a JP either. Seems like when they became non-patent, we pulled 'em.

Love

Dennie

Share this post


Link to post
Share on other sites

322 Posts; 5,674 Profile Views

had a patient come in with infected mesh...i think he was a vent. hernia repair a couple of months post-op. doc took him to surgery and ordered an antx flush thru his jp q8', so here is yet another reason we flush those jp's.

never heard of hooking a jp to wall suction...ours our usually just to bulb suction. do you guys have any policies on milking the tubing? the only time we are really encouraged to do so, is with mastectomies.

Share this post


Link to post
Share on other sites

BBFRN has 15 years experience as a BSN, PhD and specializes in Trauma,ER,CCU/OHU/Nsg Ed/Nsg Research.

3,778 Posts; 23,965 Profile Views

I'm getting more and more orders to hook up JP's to wall sxn for our post-op's these days as well.

Share this post


Link to post
Share on other sites

pebbles has 17 years experience as a BSN, RN and specializes in Trauma acute surgery, surgical ICU, PACU.

490 Posts; 7,698 Profile Views

We get sump drains to wall suction (they are bigger than JP's, and we do fush them at least BID) - NOT JP's though.

Non-patent, JP gets pulled. If pt develops another fluid collection or abscess, they'll insert another drain under CT guided visualisations.