We use Alaris pumps. During shift change, the oncoming nurse and I were doing our 2 nurse check. I had replaced the syringe at 1400. We use the BD 50ml prefilled syringes. The patient was on PCA mode only (no basal) and hadn't pushed the button so no doses were given. We cleared the pump together. However, on the PCA screen where is says VTBI "volume to be infused" it read 50.2 ml. It should have been only 50ml cause thats all the syringe will hold. We took the syringe out to start over from scratch and made sure it was programmed right (which it was) and when it restarted it said the same thing: VTBI 50.2 ml. The oncoming nurse kept questioning me why it said this. She started to make me feel uncomfortable like I had tampered with it or something. I promise I didn't add Morphine to the syringe- lol. I guess if an addicted nurse were desperate they could try and replace some Morphine they took with NS but not really sure how the pump would know there was too much added I don't know. Maybe pump malfunction? Or overfill of syringe? The Alaris pumps are relatively new to us so I have limited experience (especially with the PCAs).
Just wondering if anyone else has experienced this?
Featured Replies
Join the conversation
You can post now and register later.
If you have an account, sign in now to post with your account.
We use Alaris pumps. During shift change, the oncoming nurse and I were doing our 2 nurse check. I had replaced the syringe at 1400. We use the BD 50ml prefilled syringes. The patient was on PCA mode only (no basal) and hadn't pushed the button so no doses were given. We cleared the pump together. However, on the PCA screen where is says VTBI "volume to be infused" it read 50.2 ml. It should have been only 50ml cause thats all the syringe will hold. We took the syringe out to start over from scratch and made sure it was programmed right (which it was) and when it restarted it said the same thing: VTBI 50.2 ml. The oncoming nurse kept questioning me why it said this. She started to make me feel uncomfortable like I had tampered with it or something. I promise I didn't add Morphine to the syringe- lol. I guess if an addicted nurse were desperate they could try and replace some Morphine they took with NS but not really sure how the pump would know there was too much added
I don't know. Maybe pump malfunction? Or overfill of syringe? The Alaris pumps are relatively new to us so I have limited experience (especially with the PCAs).
Just wondering if anyone else has experienced this?