-inject air of the amount of insulin that u want to withdrawn into vial A (NPH or cloudy)
-inject air of the amount of insulin that u want to withdrawn into vial B (regular or clear)
- withdraw the insulin from vial B immediately after aspirating the air (regular or clear)
-then the amount of insulin desired from vial A (NPH or cloudy)
blynn9173
303 Posts
I am sure this is correct but wanted to double check with you all. Drawing up Insulin is like (RN).
1. Regular Insulin
2. N Insulin
3. Regular Insulin
4. N Insulin