Jan 17, 2008 09:27 PM

stringe size for arterial lines

by abcrn84

We have lost a few arterial lines lately, and are looking at our technique as a possible cause. What size syringes do you use for aspirating from alines? Do you think the size matters? We do not use the drip method, and we do return the first aspirate/waste.


Share

Search Tags
None
Top

1 Reader Gave Kudos

 
Advertisement
Sponsored Links
 
Reply
4 Comments
No. 1
from janfrn
Old Jan 17, 2008, 09:46 PM

Default Re: stringe size for arterial lines
We rarely lose an art line before it's time to pull it. The ones we lose are usually thooe that have been dislodged by a wild child (or a slightly too aggressive dressing change!). We use all sizes of syringe to draw bloodwork, from a 1 mL heparinized gas syringe up to a 20 mL for transplant workups; our patients range from neonates to virtual adults, cardiac, trauma, respiratory and all stops in between. We reinfuse the "waste" drawn off at the beginning. I've also used 3 mL, 5 mL and 10 mL syringes to flush with when the patient's art line is on a pump and not on a pressure bag. Are your flush solutions heparinized? I just glanced at a lit search reported in the AJCC that suggests more lines are lost if the flush solution infusing isn't.
Top
 
No. 2
from abcrn84
Old Jan 17, 2008, 09:50 PM

Default Re: stringe size for arterial lines
Yes, the flush has heparin.
Top
 
No. 3
from elizabells
Old Jan 17, 2008, 11:56 PM

Default Re: stringe size for arterial lines
For our Umbilical a-lines, which are either 3.5 or 5Fr and generally about 20cm long, we use 3ml syringes to aspirate and flush, although our ABG syringes are 1cc. For our peripheral art lines, which are 24g IV catheters, we use 1cc ONLY.
Top
 
No. 4
from indypicu
Old Jul 05, 2008, 03:29 PM

Default Re: stringe size for arterial lines
we use the 'vamp' system. it is a closed system you put in line when setting up the tubing. it enables you to draw off a waste, obtain sample and then return the 'waste'. its made by edwards life sciences. it is also needleless. it comes in an adult and pediatric size (basically different amts of waste pulled off) I think we lose less art line using this system. we stopped using heparin and papaverine in the flush bags and i think this had more of an impact on line patency.
Top
 
Reply




Thread Tools


Who's Online
291 members
2,157 guests
2,448

3

Four Lehigh Valley Health Network nurses accused of...

48

lawsuit - But don't most RN's work through breaks/lunch...

0

Patient Evaluation of Retail Clinic Care

7

The hard to reach on-call doctor, and its effects on...

11

Woman charged with passing off prescription drug as...

26

Man in "Vegetative State" was conscious for 23...

2

Interesting article on ThedaCare's Collaborative Care Model

14

Possible breakthrough regarding MS

63

16th Philly area hospital to stop delivering babies: Mercy...

14

Really interesting article on Indian open hearts



45

Dear preceptor

1

Society Needs Care Too

13

Why am I doing this, anyway?

2

Nurse Heal Thyself

10

My Papa, why I am the nurse I am today.

17

I made it through

11

An angel's gaze

16

A Sister Never Forgets

16

Ruby's Marbles

42

What Do Operating Room Nurses Do?

14

My Little Old Jedi

21

I love this job......

23

"I hear voices"

20

Preventing FRUTI (Foley Related Urinary Tract Infection) in...

24

Error and Attitude





Currently Reading This Page: 1 (0 members & 1 guests)

Interested in the hottest topics of the week? Subscribe to the Nurse-zine Newsletter.
Enter email address: