I'm looking for input on maintaining sterility during Foley insertion. Here's the process as per my lab instructor: Don sterile gloves, then place the sterile drape between patient's legs, then place the fenestrated drape over the patient's perineum. Our lab instructor stated that if the fenestrated drape doesn't sit quite right after you place it (like if its covering part of the perineum), that you can adjust it with your hands because you're wearing sterile gloves and the fenestrated drape is sterile. That sounds like sterile-to-sterile, but I'd still like to know what the consensus is on that?